101-DE Series

Delayed Egress Controllers

SDC’s 101-DE series delayed egress controllers incorporate all ExitCheck® features into a two piece delayed egress system where the door is closed and secured by delayed egress locking hardware. The 101-DE series delayed egress controller sends power to the slave operating magnetic locks or exit devices to lock the door in a secured position. The integrated digital display on the 101-DE controllers provide an alternating verbal message, verbal countdown and alarm tone, plus a large digital countdown display and door release indicator to provide a clear warning for the safety of persons without prior knowledge of door operation, including the blind and hearing impaired. A built-in three function digital keypad provides reset, and timed or sustained bypass. Designed to delay egress through perimeter exit doors for 15 or 30 seconds, alert security and personnel to unauthorized egress, and are compatible with access controls and patient wandering systems.

A choice of operation mode allows users to meet their local code compliance while meeting all national and regional building and fire life safety codes, including NFPA 101, Special Locking Arrangements. All SDC delayed egress locks release immediately in an emergency.

101-DE series delayed egress controllers must be ordered with a magnetic lock or exit device with ExitCheck® slave operation feature to secure the door. Designed to control up to two doors, order two magnetic locks or two exit devices for double door applications

x See Datasheet For More Info
  • UL 294 Access Control System Units
  • UL 10B Fire Tests of Door Assemblies
  • UL 10C Positive Pressure Fire Tests of Door Assemblies
  • ULC-S104 Standard Method for Fire Tests of Door Assemblies
  • ULC-S533 Egress Door Securing and Releasing Devices
  • NFPA 101 Life Safety Code Special Locking Arrangements
  • NFPA 1-UFC Uniform Fire Code
  • UBC Uniform Building Code Standard 7-2 Fire Test of Door Assemblies (1997)
  • IBC International Building Code Delayed Egress Locks  
  • IFC International Fire Code Delayed Egress Locks
  • SBC Standard Building Code
  • CBC, California Building Code Special Egress Control Devices
  • BOCA National Building Code Special Locking Arrangements
  • Chicago Building Code Electro-Magnetic Locking Devices
  • CSFM Listed 3774-0324:0103

* All installations must be approved by the local Authority Having Jurisdiction (AHJ).

101-KDENA
Delayed Egress Controller, Keyswitch Reset, NFPA 101, Selectable Egress Delay
101-DENA
Delayed Egress Controller, NFPA 101, Selectable Egress Delay
1511DEV
Single Slave EMLock,1650lbs, 628
1581DEV
Single Slave EMLock, 650lbs, 628
CYL-6KAQ
Mortise Cylinder 6-Pin, 1-1/8” Length, Keyed Alike
CYL-6KDQ
Mortise Cylinder, 6-Pin, 1-1/8” Length, Keyed Different
1 See Complete List