Pre-Built System Wire Diagrams
The Pre-Built Systems Library provides a choice of several Complimentary system wire diagrams for common single and double door applications. Drawings vary with choice of different locking hardware and access and egress controls. Several of the same or different drawings may be used to accommodate multi-door system requirements.

Website visitors can use the drawings as a guide to assist in system specification and pricing using the SDC System Wizard. Distributors and dealers can use these drawings as a selling tool by including them in their quotations and proposals. Installers may present the drawing information or component inventories to the distributor as a shopping list or RFQ.

All drawings Include:
. Riser Diagram
. Point-to-Point Diagram
. Component Inventory
. Written Method of Operation

More Drawings Coming Soon
As this is a work in progress, please check this page periodically as more diagrams will be added monthly.

Click on drawing number to download and print pre-built systems.
Electromagnetic Lock System


Drawing: DWG0033
Single Door
1. E4KP Stand Alone Card Reader
2. Magnetic Lock, 1650lbs, 1200lbs or 650lbs
3. Exit Switch
4. Power Supply w/Emergency Release

Method Of Operation
Access/Egress: Presenting an authorized card to the reader releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by the card reader programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0001-R2
Single Door
1. Integrated Outdoor Keypad
2. Magnetic Lock, 1650lbs
3. Exit Switch
4. Power Supply w/Emergency Release

Method Of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by digital keypad programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0003-R2
Single Door
1. Integrated Keypad
2. Magnetic Lock, 1650lbs
3. Exit Switch
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by digital keypad programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0005-R2
Pair of Doors
1. Integrated Outdoor Keypad
2. Double Magnetic Lock, 1200lbs or 1650lbs
3. Exit Switch
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by digital keypad programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0006-R2
Pair of Doors
1. Integrated Keypad
2. Double Magnetic Lock, 1200lbs or 1650lbs
3. Exit Switch
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by digital keypad programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.


Electrified Lockset Systems


Drawing: DWG0034
Single Door
1. E4KP Stand Alone Card Reader
2 .Electrified Mortise Lockset – Z7850 Failsafe
3. Electric Hinge
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Presenting an authorized card to the reader releases the lever of the locking device momentarily for access. Entry momentary unlock time is determined by the card reader programming. Egress will be free at all times.
Emergency Release:All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: DWG0035
Single Door
1. E4KP Stand Alone Card Reader
2 .Electrified Mortise Lockset – Z7852 Failsecure
3. Electric Hinge
4. Power Supply

Method of Operation
Access/Egress: Presenting an authorized card to the reader releases the lever of the locking device momentarily for access. Entry momentary unlock time is determined by the card reader programming. Egress will be free at all times.



Drawing: 1-RS/1-PP-Library-0007-R2
1. Integrated Outdoor Keypad
2. Electrified Mortise Lockset x REX Output
3. Power Transfer Hinge
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by digital keypad programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0008-R2
1. Integrated Outdoor Keypad
2. Electrified Mortise Lockset x REX Output - Failsecure
3. Power Transfer Hinge
4. Power Supply

Method of Operation
Access/Egress: Entering a valid digital code releases the lever of the locking device momentarily for access. Entry momentary unlock time is determined by digital keypad programming. Exit will be free at all times. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0009-R2
Single Door
1. Integrated Keypad
2. Electrified Mortise Lockset x REX Output
3. Power Transfer Hinge
4. Power Supply w/Emergency Release

Method of Operation
Access/Egress: Entering a valid digital code releases the lever of the locking device momentarily for access. Entry momentary unlock time is determined by digital keypad programming. Exit will be free at all times. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.



Drawing: 1-RS/1-PP-Library-0010-R2
Single Door
1. Integrated Keypad
2. Electrified Mortise Lockset x REX Output - Failsecure
3. Power Transfer Hinge
4. Power Supply

Method of Operation
Access/Egress: Entering a valid digital code releases the lever of the locking device momentarily for access. Entry momentary unlock time is determined by digital keypad programming. Exit will be free at all times.


Electric Strike Systems

Drawing: 1-RS/1-PP-Library-0011-R2
Single Door
1. Integrated Keypad
2. Heavy Duty Electric Strike - Failsecure
ANSI 4 7/8" for Cylindrical Lock
3. Power Supply

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Entry momentary unlock time is determined by digital keypad programming. Exit will be free at all times by turning the inside lever. Sustained Bypass: When so programmed, entering a bypass code unlocks the door for a sustained period until manually reset.



Drawing: 1-RS/1-PP-Library-0012-R2
Single Door
1. Integrated Keypad
2. Heavy Duty Electric Strike - Failsecure
ANSI 4 7/8" for Cylindrical Lock
3. Power Supply

Method of Operation
Access/Egress: Entering a valid digital code releases the locking device momentarily for access. Entry momentary unlock time is determine

 
Toll Free: 1.800.413.8783 Tel: 1.805.494.0622 USA Fax: 1.805.494.8861 E-mail: service@sdcsecurity.com